What Is the Fault When the Frequency Inverter Does Not Respond When Powered On?

In daily industrial operations, encountering a situation where a frequency inverter does not respond when powered on is not uncommon. Typically, a variable frequency drive (VFD) or variable frequency inverter will display error codes to indicate faults. However, when there is no response at all, it raises concerns. So, what could be the possible reasons for such an issue, and how should it be diagnosed?

Frequency-Inverter-does-not-respond-powered-on (1)

What Are the Troubleshooting Methods?

Diagnosing an unresponsive inverter VFD requires systematic troubleshooting to identify and resolve the underlying issues. Below are some methods to approach the problem:

1. Check the Power Switch

First, verify the power switch’s condition. A faulty power switch can prevent the variable speed drive from starting. Replacing the defective switch can often resolve the issue.

2.Perform a Static Test

Use a multimeter to measure resistance values and check for balance:

  • Set the multimeter to the resistance (X10) range.
  • Connect the red probe to the inverter’s P terminal and the black probe to R, S, and T terminals one by one. The measured resistance should be approximately tens of ohms and balanced across all three readings.
  • Reverse the probes: connect the black probe to the P terminal and the red probe to R, S, and T terminals. The resistance values should approach infinity.

Repeat the test for the N terminal. If the results match the expected values, the static test is normal.

3. Perform a Dynamic Test

Start the variable frequency inverter in a no-load condition and observe the U, V, and W three-phase output voltage:

  • Check for missing phases or imbalance, which could indicate faults in modules or driver boards.

If the output voltage is normal, proceed with a load test to evaluate performance under operational conditions.

What Are the Solutions?

After identifying the fault, apply the following corrective measures:

1. Power Supply Issues

Ensure the power supply is functioning correctly. Verify voltage levels and continuity to guarantee the frequency inverter receives adequate power.

2. Parameter Setting Errors

Check the inverter VFD‘s parameter settings. Incorrect settings may cause the drive to malfunction. Confirm that the settings align with the motor’s specifications.

3. External Control Signal Issues

Inspect external control signals from PLCs or other controllers. Ensure the signals are properly configured and transmitted to the variable speed drive.

4. Module or Driver Board Faults

If dynamic testing reveals missing phases or imbalances, these issues often point to faults in the module or driver board. Replacing the faulty components is necessary to restore normal operation.

Conclusion

When a variable frequency drive or inverter VFD does not respond when powered on, systematic troubleshooting is key to identifying and resolving the issue. By carefully checking the power supply, performing static and dynamic tests, and addressing control signal or hardware faults, these problems can be effectively resolved. Regular maintenance and monitoring of frequency inverters can also help prevent such issues, ensuring uninterrupted operation in industrial environments.